All kinds of communication methods available
Shine WiFi-x
Shine4G-x
ShineLan-x
ShineLink-x
Powerful free platforms for global customers Growatt Monitoring Platform ● Max. efficiency 98.4% ● Dual MPP trackers ● Type II SPD on DC side ● Battery ready, future proof 24h self-consumption monitoring
| Datasheet | MIN 2500TL-X | MIN 3000TL-X | MIN 3600TL-X | MIN 4200TL-X | MIN 4600TL-X | MIN 5000TL-X | MIN 6000TL-X | |
| Input Data (DC) | ||||||||
| Max. recommended PV power (for module STC) | 3500W | 4200W | 5040W | 5880W | 6440W | 7000W | 8100W | |
| Max. DC voltage | 500V | 500V | 550V | 550V | 550V | 550V | 550V | |
| Start voltage | 100V | |||||||
| Nominal voltage | 360V | |||||||
| MPP voltage range | 80V-500V | 80V-500V | 80V-550V | 80V-550V | 80V-550V | 80V-550V | 80V-550V | |
| No. of MPP trackers | 2 | |||||||
| No. of PV strings per MPP tracker | 1 | |||||||
| Max. input current per MPP tracker | 13.5A* | |||||||
| Max. short-circuit currentper MPP tracker | 16.9A | |||||||
| Output data (AC) | ||||||||
| AC nominal power | 2500W | 3000W | 3600W | 4200W | 4600W | 5000W | 6000W | |
| Max. AC apparent power | 2500VA | 3000VA | 3600VA | 4200VA | 4600VA | 5000VA | 6000VA | |
| Nominal AC voltage (range*) | 230V (180-280V) | |||||||
| AC grid frequency (range*) | 50/ | 60 Hz (45-55Hz/55-65 | Hz) | |||||
| Max. output current | 11.3A | 13.6A | 16A | 19A | 20.9A | 22.7A | 27.2A | |
| Adjustable power factor | 0 | .8leading…0 .8laggin | g | |||||
| THDi | <3% | |||||||
| AC grid connection typeEfficiency | Single phase | |||||||
| Max.efficiency | 98.2% | 98.2% | 98.2% | 98.4% | 98.4% | 98.4% | 98.4% | |
| European efficiency | 97. 1% | 97. 1% | 97.2% | 97.5% | 97.5% | 97.5% | 97.5% | |
| MPPT efficiency | 99.9% | |||||||
| Protection Devices | ||||||||
| DC reverse polarity protection | yes | |||||||
| DC switch | yes | |||||||
| AC/DC surge protection | Type III / Type II | |||||||
| Insulation resistance monitoring | yes | |||||||
| AC short-circuit protection | yes | |||||||
| Ground fault monitoring | yes | |||||||
| Grid monitoring | yes | |||||||
| Anti-islanding protection | yes | |||||||
| Residual-current monitoring unit | yes | |||||||
| AFCI protectionGeneral Data | Optional | |||||||
| Dimensions (W / H / D) | 375/350/160mm | |||||||
| Weight | 10.8kg | |||||||
| Operating temperature range | –25°C ... +60°C | |||||||
| Noise emission (typical) | ≤35 dB(A) | |||||||
| Nighttime power consumption | < 1W | |||||||
| Topology | Transformerless | |||||||
| Cooling | Natural convection | |||||||
| Protection degree | IP65 | |||||||
| Relative humidity | 0- 100% | |||||||
| Altitude | 4000m | |||||||
| DC connection | H4/MC4(Optional) | |||||||
| AC connection | Connector | |||||||
| Display | OLED+LED/WIFI+APP | |||||||
| Interfaces: RS485 / USB/Wi-Fi/ GPRS/ RF/LAN | Yes/Yes/Optional/Optional/Optional /Optional | |||||||
| Warranty: 5 years / 10 years | Yes /Optional CE, IEC62109, VDE0126- 1- 1, AS4777, AS/NZS 3100, VDE-AR-N4105, CQC, IEC61683, IEC60068, IEC61727, IEC62116, INMETRO | |||||||